RAID data recovery · server & NAS array

RAID Data Recovery – recover a RAID array & NAS array

RAID array degraded, rebuild failed or several drives failed at once? We recover data from RAID 0, RAID 1, RAID 5, RAID 6 and RAID 10 arrays – for hardware and software RAID in server and NAS systems, in our ISO-certified cleanroom lab.

  • ✅ RAID 0, 1, 5, 6 & 10
  • ✅ Server & NAS systems
  • ✅ Diagnosis with a binding fixed price
  • ✅ Manufacturer-independent
4,8/5 458 reviews
> 95 % success rate
20+ years of experience
TÜV-certified customer service ISO 9001 – quality management Cleanroom laboratory GDPR- & BDSG-compliant Transparent fixed prices

A RAID array protects against the failure of individual hard drives or SSDs – but it is no substitute for a backup. If more than one drive fails at the same time, a rebuild aborts, the controller reports an error or the entire volume is suddenly no longer shown, acute data loss is imminent – but in most cases professional data recovery is still possible. It is crucial to take the array out of service immediately, not to start a rebuild yourself, not to change the order of the drives and not to allow any further access.

The RAID systems we recover

We work independently of the manufacturer on all common form factors, models and capacities.

RAID 0, 1, 5, 6 & 10

Striping, mirroring, distributed parity or combinations – we reconstruct all common RAID levels virtually in the lab.

Hardware- & Software-RAID

RAID controller arrays as well as software RAID on Windows, Linux (mdadm) or macOS.

Server- & NAS-RAID

Production and backup servers as well as NAS systems with several hard drives (HDD) or SSDs in an array.

USB- & Desktop-RAID

Smaller RAID arrays in USB enclosures or desktop systems with several drives.

RAID manufacturers we work with

Data recovery is carried out independently of the manufacturer – among others for manufacturers such as:

Typical damage patterns in RAID failures

Whether mechanical, electronic or logical – the fault pattern determines the right procedure.

Degraded

Array in degraded mode

One drive has failed, the RAID array is only running in emergency mode without redundancy. Act now before a second drive follows.

Multiple failure

Several drives faulty at once

With RAID 5 or 6, the failure of several drives can overwhelm the parity – the array collapses completely and is no longer visible to the operating system.

Rebuild

Rebuild failed or aborted

A failed or manually aborted rebuild can overwrite existing data. No further rebuild attempt should be started without a professional check.

Controller

Controller or firmware fault

A defective RAID controller or faulty firmware can lose the configuration of the storage system, even though the individual hard drives or SSDs themselves are still intact.

Power outage

Power outage & overvoltage

A power outage or overvoltage during a write operation can damage the RAID configuration and affect several drives at once – the volume often can no longer be mounted afterwards.

Logical

Deleted volumes & file system errors

Accidentally deleted files, a damaged file system or a configuration error affect the entire array – even without a hardware fault, data loss is a threat.

First aid for a RAID failure

With the right immediate measures you significantly increase the chance of a complete recovery:

RAID in use: servers, NAS & databases

RAID arrays form the backbone of many storage systems: they carry databases, file and mail servers as well as the datastores of VMware and Hyper-V environments. If the array fails, an entire company can quickly grind to a halt.

Not every multi-drive system is redundant: a JBOD or a RAID 0 offers no protection against a hard drive failure. We recover data from arrays with hard drives (HDD), SSDs and mixed configurations – internal as well as in external enclosures, on Windows, Linux and Mac.

Causes of data loss in RAID

The most common causes and reasons for data loss in RAID range from hardware to configuration problems. Typical error messages and damage to the configuration are early indicators:

Multiple failure

More drives faulty than the redundancy of the RAID level can tolerate.

Power outage

Overvoltage or a power outage damages the configuration.

Rebuild error

An aborted rebuild overwrites existing data.

Human error

Accidentally deleted volumes or wrong drive order.

Virtual reconstruction: the process in the lab

The process: first our technicians clone each drive sector by sector. Then the specialists reconstruct stripe size, drive order and parity information virtually on the copies – the repair or recovery never takes place on the original.

This technology allows our experts to reconstruct even heavily damaged arrays. For time-critical failures an express service with priority handling is available.

How your RAID data recovery works

1

Consultation

Free initial assessment of your RAID damage by phone.

2

Submission

Shipping or pickup of all drives in the array – throughout Germany.

3

Analysis

Diagnosis of controller, configuration and drives including a diagnostic report.

4

Fixed price

Binding fixed-price offer – your cost estimate before the recovery.

5

Reconstruction

Virtual reconstruction of the array and data recovery in the lab.

6

Handover

Secure, encrypted handover of your recovered data.

Diagram of RAID 5 with distributed parity across several hard drives, stripes and data recovery after the failure of one drive © cyber-tech.de · RAID data recovery
RAID 5: data and parity are distributed across all drives – if one fails, the content can be reconstructed from them.

In our data recovery lab all drives in the array are first cloned sector by sector. The virtual reconstruction of the array then takes place based on stripe size, drive order, parity and file system – exclusively on the copies, so that the original drives remain unchanged.

What does RAID data recovery cost?

The final price depends on the damage and the effort involved – which is why we do not quote it as a flat rate, but only after the diagnosis, and then bindingly as a fixed price.

from 69 €Diagnosis incl. diagnosis report and recoverability assessment
Fixed pricebinding before the recovery – no hidden costs, no vague estimate
0 €no data, no cost – you only pay for the recovery on success

Frequently asked questions about RAID data recovery

What does data recovery from a RAID system cost?
The analysis is subject to a charge (from €69) and covers the diagnosis of the controller, the configuration and all drives including a diagnostic report. You then receive a binding fixed-price offer. The principle applies: no data – no charge.
Should I start a rebuild when a drive in the RAID has failed?
With an already degraded array, an uncontrolled rebuild can irrevocably overwrite existing data, especially if another drive shows signs of weakness. Recovery software or a rebuild attempt on your own carry a high risk when several drives are affected – have the condition checked professionally beforehand instead of changing the drive order or the configuration yourself.
What are the most common causes of data loss in a RAID?
The most common causes include the simultaneous failure of several drives, a power outage during operation, a failed rebuild, a controller fault and human error in the configuration.
Why is a RAID not enough as a backup?
RAID increases the fault tolerance of individual drives but does not protect against ransomware, accidentally deleted files, controller faults or an error in the configuration that affects the entire array. An additional, separate backup remains necessary.
What does virtual reconstruction of a RAID array mean?
In the lab all drives are first cloned sector by sector. The reconstruction of stripe size, drive order, parity and file system then takes place exclusively on the copies – the original drives remain untouched.
Can data recovery succeed even with a NAS that has several drives failed at once?
In many cases yes. Even if more drives have failed than the redundancy of the RAID level allows, the array can often be reconstructed from individual still-readable areas and the original configuration.
Is there an express service for failed RAID systems?
Yes. Because a RAID failure often brings company operations to a standstill, we offer an express service with priority handling for time-critical cases.
Which RAID levels can be recovered?
From years of experience with RAID arrays in companies, we reconstruct RAID 0, RAID 1, RAID 5, RAID 6, RAID 10 as well as proprietary arrays from NAS manufacturers such as Synology or QNAP – regardless of whether it is a hardware or software RAID.

RAID failed? We help immediately.

  • Manufacturer-independent
  • Diagnosis with a binding fixed price
  • No data – no cost
Request data recovery

24/7 consultation

Tel.: 0800 / 937 88 36

RAID data recovery in your region

RAID data recovery Recover data now